CONNECT KEYBOARDS

Pelco offers three keyboard models for use with the CM6700 matrix switcher. Complete in-
stallation instructions are provided with each keyboard. The most common connections are
for local and remote keyboards. The procedures for installing local and remote keyboards
are repeated here. Refer to the keyboard manual for the less common ASCII connection
(KBD200A only).

Do the following to install. Refer to Figure 19.

1.

Local keyboard. Using the data cable that is supplied with the keyboard, plug one end
into the RJ-45 connector on the rear of the keyboard and plug the other end into the
LOCAL KEYBOARD port on the SCU. Set the keyboard DIP switch for the desired
address for the local keyboard (refer to Table A).

If you are not installing any other keyboards, go to the

Programming

section. To install

remote keyboards, complete steps 2-10.

2.

Select a suitable location for each keyboard and wall block. Wall blocks must be within
6 feet (1.8 m) of a suitable electrical outlet. Do not mount the wall block yet.

3.

Run wall block interconnect cable (user-supplied) from the SCU to the closest key-
board location, and then to the next nearest location, and the next, etc.

Communication to the keyboards is RS-485. Maximum total cable distance for RS-485
communication over 24-gauge wire is 4,000 feet (1,219 m). Pelco recommends using
shielded twisted pairs cable that meets or exceeds the basic requirements for EIA
RS-485 applications.

4.

Remove the wall block cover and make cable connections at each wall block.

5.

At each wall block, wire the transformer to pins 3 and 4. Polarity is unimportant.

6.

Replace the cover on the wall block. Secure the wall block to a suitable surface.
A double-sided sticky pad is provided to mount the wall block.

7.

Set the address switches for each keyboard according to Table A.

NOTE:

A KBDKIT or

KBDKIT-X is required to
connect remote keyboards.
The KBDKIT consists of two
RJ-45 wall blocks and one
120 VAC to 12 VAC trans-
former. The KBDKIT-X is for
230 VAC. Use one wall block
for each keyboard.

Figure 19. Installing Local and Remote Keyboards

25-FOOT KEYBOARD DATA

KBD

LOCAL
KEYBOARD

LOCAL

KEYBOARD

REMOTE KEYBOARD(S)

USER-SUPPLIED CABLE
TO REMOTE KEYBOARDS

CM6700 SCU

25-FOOT KEYBOARD

DATA CABLE

2

3

4

5

6

7

1

8

25-FOOT KEYBOARD

DATA CABLE

2

3

4

5

6

7

1

8

RX+
RX-

TX+

TX-

GND

TO ADDITIONAL
KEYBOARDS

REMOTE KEYBOARD

12 VAC

12 VAC

WALL BLOCK TERMINALS

WALL BLOCK TERMINALS

REMOTE KEYBOARD