2mount unit – Pelco CM6700 User Manual

Page 9

Advertising
background image

Pelco Manual C523M-H (6/05)

9

3.

Refer to Figure 6. Set DIP switches.

a.

Communication port 2 is available for a PC or remote keyboard operating in ASCII
mode. (Refer to

ASCII Operating Commands

.) Most PC applications require

RS-232. A remote keyboard can require either RS-232 or RS-422, depending on
the communications facility. To find out the required interface, check your PC
serial port information or refer to your keyboard manual. Set DIP switch SW5
(COM 2) for RS-232 or RS-422, according to your system requirements. The
SCU is configured at the factory for RS-422.

b.

DIP switches SW1, SW2, SW3 and SW4 are to remain in the factory default posi-
tion (OFF).

c.

DIP switch SW6 (COM1) is to remain in factory default position (RS-422).

Figure 6. DIP Switch Locations

4.

Replace cover.

2

MOUNT UNIT

1.

Select a suitable location for the SCU. It must be within 6 feet (1.8 m) of a suitable
electrical outlet. Do not connect the power yet.

2.

Refer to Figure 7. Position mounting ears on the sides of the SCU for the appropriate
mounting. If the ears are not required, leave them off.

ON

1 2 3 4

ON

1 2 3 4

ON

1 2 3 4

ON

12345678

ON

12345678

POWER
TERMINAL
BLOCK

FUSE

TRANSFORMER

ON

12345678

ON

SW5 & 6 DIP SWITCH SETTINGS

RS-422/485

RS-232

12345678

OFF

KEY

ON

SW6 DEFAULTS
TO RS-422

3c

3a

3b

ON

1 2 3 4

HIGH VOLTAGE

00054

Figure 7. Installing Mounting Ears

POSITION BRACKETS FOR
FLUSH MOUNTING
(WALL OR TABLE TOP)

POSITION BRACKETS FOR
UNDER-TABLE MOUNTING

POSITION BRACKETS FOR
RACK MOUNTING (REAR)

NOTE: EACH SCU COMES WITH

2 MOUNTING BRACKETS