Installation, 1set options, Figure 4. cover removal – Pelco CM6700 User Manual

Page 8: Figure 5. video termination jumpers

Advertising
background image

8

Pelco Manual C523M-H (6/05)

INSTALLATION

1

SET OPTIONS

1.

Refer to Figure 4. Remove the cover.

Figure 4. Cover Removal

2.

Refer to Figure 5. Set jumpers according to your system requirements. JP1-JP16 are
used to terminate the video input with a 75-ohm resistor or to unterminate the video
(looping). The factory default has the jumper installed in the terminating position. If you
are connecting only a camera to an input, leave the jumper in the terminating position.
If you are looping the video to another device, move the jumper to the looped position,
and terminate at the equipment connected to the looping output.

REMOVE 6
SCREWS

REMOVE 6
SCREWS

LIFT COVER
OFF

A

B

C

00055

ON

1 2 3 4

ON

1 2 3 4

ON

1 2 3 4

75-OHM TERMINATION
JUMPERS (ONE PER INPUT)

ON

1 2 3 4

BACK OF SCU

JP1

JP16

NOTE: JUMPER JP1 CORRESPONDS TO VIDEO INPUT 1,

JP2 TO VIDEO INPUT 2, ETC.

75-OHM TERMINATION

JUMPER

TERMINATED LOOPED

KEY

Figure 5. Video Termination Jumpers