Pelco CM6700 User Manual

Page 30

Advertising
background image

30

Pelco Manual C523M-H (6/05)

Table B. Programming the CM6700 Switching Control Unit (Continued)

Step

7

Function

Action

Result

Program

a. Enter the Main Menu.

Alarms 17 & 18

b. Press 4.

c. Press 2.

d. Move down to the ENABLE field.

e. Use the F1 and F2 keys to toggle the Alarm Enable

field (* = ON, -- = OFF). If you selected OFF go to
step q. Otherwise go to the next step.

f. Pan right.

g. Use the F1 and F2 keys to toggle the Alarm TYPE

field (NO = normally open contacts, NC = normally
closed contacts).

h. Move down to the MON1/CAM1 field in the Macro

matrix.

i.

The entry indicates which camera will be displayed
first on monitor number 1 when the Macro alarm is
activated. Use the keypad to enter the desired
camera number.

j.

Use the pan and tilt to move through the matrix and
assign the cameras to the sequence for each monitor.
If a monitor is not to be included in the sequence,
enter all zeros.

k. When you have completed all entries, move down to

MACRO PRESET MENU.

l.

Pan right.

m. The entry indicates which preset will be assumed by

the MON1/CAM1 camera when the Macro alarm is
activated. Use the keypad to enter the desired preset
number.

The Main Menu appears.

The Set Alarm Input screen appears. Alarms are
programmed in two groups. The Group 1 (INPUT 1-
16) number flashes.

The Set Alarm Input 17 screen appears. The number
17 flashes.

The entry in the ENABLE field flashes.

The selected value flashes.

The entry in the TYPE field flashes.

The selected value flashes.

The entry in the MON1/CAM1 field flashes.

The entered value flashes.
The selected value flashes.

Each selected value flashes.

The M in MACRO PRESET MENU flashes.

The Macro 1 (or 2) Presets screen appears.
The entry in the MON1/CAM1 field flashes.

The entered value flashes.

PROCEDURE METHOD

PROCEDURE METHOD

F1/F2

F1/F2

Keypad

MON CAM1 CAM2 CAM3 CAM4

Turn alarm on/off
(*/--).

Select alarm source Type
(NO, NC).

Assign 4 inputs for each
monitor to sequence.

Assign Preset
for each input
in sequence.

F1/F2

Select 17 or 18.

SET ALARM INPUT

1. INPUT 1-16
2. INPUT 17 AND 18

RETURN

ALARM INPUT XX

MACRO X

ENABLE: --

TYPE: NO

MACRO PRESET MENU

RETURN

1 01 02 03 04
2 05 06 07 08
3 09 10 11 12
4 13 14 15 16

MACRO X
PRESETS

MON CAM1 CAM2 CAM3 CAM4

PRE PRE PRE PRE

1 00 00 00 00
2
3

00 00 00 00
00 00 00 00
00 00 00 00

RETURN

Keypad

(Continued on next page)

Advertising