Pelco CM6700 User Manual

Page 40

Advertising
background image

40

Pelco Manual C523M-H (6/05)

Table E. Solutions To Common Problems

Problem

Remedy

CM6700 does not have power.

Make sure the power cord is plugged in.

Check the fuse. Refer to Figure 6 for the fuse location.

You can see some cameras and not others

Confirm that the camera is properly connected and has power.

from your location.

The keyboard and monitor may have been denied access to the cameras.

The CM6700 does not respond to key-

Confirm that the monitor the keyboard is addressing is the same as the monitor in

board commands.

front of you.

Pressing the PGM key displays a P on the

Confirm that the keyboard transformer is plugged in and all electrical connections

keyboard LED but the Password menu

are in order.

does not appear on the menu.

Confirm that the monitor the keyboard is addressing is the same as the monitor in
front of you.

Upon initial system startup, the alpha-

Jumper JP17 on the motherboard is in the wrong position. Remove the cover and

numeric monitor display is in the middle

change JP17 to the opposite position. Instructions for switching video termination

of the screen or is not seen.

jumpers in the

Set Options

section are a similar process.

Keyboards do not function after installation

Confirm that all wiring is correct and that keyboards have power and are connected.

and initial power-up.

Confirm that all keyboards are addressed differently.

Previous system control has been lost.

First, try initializing the keyboard by entering the monitor number followed by
pressing the MON key. If this does not restore control…

Second, try unplugging the data cable from the rear of the keyboard and then
plugging it back in. Then re-initialize the keyboard. If this does not restore control…

Third, power down the CM6700, power back up, and then re-initialize keyboards.
If this does not restore control…

Fourth, perform a software reset (refer to

Performing a Software Reset

in this

section). If this does not restore control, call Pelco at 1-800-289-9100.

Cannot gain keyboard and ASCII port PTZ

You must wait at least five seconds after a separate user has stopped before you

control after another user has stopped

can gain control.

controlling.

The unit malfunctions and you cannot

Perform a software reset (refer to

Performing a Software Reset

in this

restore it to satisfactory operation.

section).

The keyboard transformer must be

If a 12 VAC transformer is unavailable, you can use a 12 VDC transformer.

replaced.

Polarity is unimportant when wiring the transformer to the wall jack.

Table F. Switcher/Controller and Keyboard RJ-45 Pin Functions

Switcher/Controller

Keyboards

Pin

Function

Pin

Function

1

RX+

1

TX+

2

RX-

2

TX-

3

12 VAC

3

12 VAC/DC

4

12 VAC

4

NON-POLAR

5

Ground

5

Ground

6

NC

6

NC

7

TX-

7

RX-

8

TX+

8

RX+

NC = No connection