3.2.2 Calculating heat quantity

For power consumption, allow for 600 VA (

600 W) per unit. Since most of the power consumed is transformed into

heat, power consumption may be regarded as roughly equal to generated heat.

1 Conversion to calories

[W] x 0.86 = [kcal/h]

Heat generated per display: 600 W x 0.86 = 516 kcal/h

2 Conversion to British Thermal Units (BTU)

[W] x 3.41 = [BTU/h] Heat generated per unit: 600 W x 3.41 = 2046 BTU/h

3.2.3 Product mounting holes

We recommend using mounting hardware available from Pioneer. If you use other mounting hardware, attach them to

the unit using the M8-bolt holes provided in the unit. Remove the hole rivets, depending on the particular mounting

hardware used. Tighten bolts with a torque between 50 and 80 kg.cm. Applying a torque beyond these limits may lead

to nut failure.

• Locations of useble mount holes are shown below. (Caps, or plugs, can be removed by turning them with a coin or

another device.)

Air outlet (Fan)

Hole “b”

Hole “a”: in 6 locations

Hole “b”: in 18 locations

Center line

Hole “b”

Hole “b”

Hole “b

Center

line

Hole “b”

Hole “b”

Hole “a”

Hole “a”

Rear View

Mounting Surface

Mount

hardware,

etc.

Hole “a”

Hole “b”

Bolt

10 to 23mm

Installation Conditions

Always use a minimum four mounting holes, evenly distributed on opposite sides of both the horizontal and

vertical center lines.

Use bolts that can be driven 10 to 17-mm into holes “a” or 10 to 23-mm into holes “b,” as shown in the Side View

above.

Do not block or cover air outlets and openings for ventilation on the rear panel. Take precautions to prevent fouling

walls behind the product with exhaust air discharged from the air outlets.

This unit incorporates glass components. Install only on flat surfaces.

Bolt

10 to 17mm

Side View