Pc control, Interface, 8 bits – NEC GT2000 User Manual

Page 26: E-26, Remote 2/pc connector control data format

Advertising
background image

E-26

PC Control

Interface

An RS-232C cable enables you to use your PC as a controller for your projector.

* RS-232C (Straight cable)
* Baud rate: ................................ 9600 bps
* Data length: ............................. 8 bits
* Parity: ...................................... Odd parity
* Stop bit: ................................... 1 bit
* Communications procedure: ... Full duplex

Signal Name

Signal Ground

Receive Data

Transmit Data

Clear To Send

Request To Send

-

Not Connected

Function

Ground

Data reception

Data transmission

Reception interrupt

Transmission interrupt

Used iside the projector (Should always be left open)

Not used

Pin No.

9, 15

6

7

12

8

1, 2

3-5, 10, 11, 13, 14

I/O

-

I

O

I

O

-

-

5

1

2

3

4

10

6

7

8

9

15

11

12

13

14

* Command specification code: This code specifies whether the

command is a single control command or a multiple control
command.
A single control command (C0H) is valid for only the projector
specified by the unit address.
A multiple control command (C1H) is valid for all projectors
which receive the command, regardless of the unit address. Note
that only projectors in agreement with the unit address will
return an ACK.

* Unit address: This code specifies the ID of the projector (0-64).

You can select the [Settings Menu]->[Projector ID] under the
main menu and specify the ID of projector.
For a single projector, the ID should be set at 0.

8 bits

8 bits

8 bits

8 bits

8 bits

• • • • • • • • •

CKS

Command

specification code

Unit

address

Function

number

Data

length

Data

* Function number: The function's identification code.
* Data length: This specifies the number of bytes of data (not

including CKS).

* Data: The parameters attached to the function.
* CKS (check sum): The lower-order 8 bits of the calculation

results from the first byte (i.e., the command specification code)
to the byte in front of CKS.

REMOTE 2/PC Connector

Control Data Format

EMOTE 1

B 1 AUDIO

REMOTE 2/PC

EXT-CTL

REMOTE

OUTPUT

REMOTE

INPUT

NO

R

To RS232C

RS232C straight cable

Signal source

Advertising
This manual is related to the following products: