Connecting multiple iss-6020 switchers – NEC GT2000 User Manual

Page 33

Advertising
background image

E-33

Setting The Data
When the EX PW pin is low, the power is on; when high, the
power is off.

When the EX MT pin is low, Picture Mute is on; when high,
Picture Mute is off.

EX PW

Low

High

Power

ON

OFF

Note: Channel settings are only valid when the ISS-6020 is connected.

Note: If a channel is switched to another using the remote control when the external control is valid, the channel is forced to switch to
the one set by the external control.

Connecting A Single ISS-6020 Switcher

Slot

1

2

3

4

5

6

7

8

9

10

Channel Number

1

2

3

4

5

6

7

8

9

0

EX C6

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

EX C5

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

EX C4

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Hi

EX C3

Hi

Hi

Hi

Hi

Hi

Hi

Hi

Lo

Lo

Hi

EX C2

Hi

Hi

Hi

Lo

Lo

Lo

Lo

Hi

Hi

Hi

EX C0

Lo

Hi

Lo

Hi

Lo

Hi

Lo

Hi

Lo

Hi

EX C1

Hi

Lo

Lo

Hi

Hi

Lo

Lo

Hi

Hi

Hi

Connecting Multiple ISS-6020 Switchers

Master Slot

1

1

1

1

9

9

9

10

10

10

10

Slave Slot

1

2

3

4

8

9

10

1

2

9

10

Channel Number

11

12

13

14

98

99

90

01

02

09

00

EX C6

Hi

Hi

Hi

Hi

Lo

Lo

Lo

Hi

Hi

Hi

Hi

EX C5

Hi

Hi

Hi

Hi

Lo

Lo

Hi

Hi

Hi

Hi

Hi

EX C4

Hi

Hi

Hi

Hi

Hi

Hi

Lo

Hi

Hi

Hi

Hi

EX C3

Lo

Lo

Lo

Lo

Hi

Hi

Lo

Hi

Hi

Lo

Hi

EX C2

Hi

Lo

Lo

Lo

Hi

Hi

Hi

Hi

Hi

Hi

Hi

EX C1

Lo

Hi

Hi

Lo

Lo

Lo

Lo

Hi

Lo

Hi

Hi

EX C0

Lo

Hi

Lo

Hi

Hi

Lo

Hi

Lo

Hi

Lo

Hi

To calculate:

EX C6-EX C0 can be presented in binary; Lo=1 and Hi=0

Convert a decimal number (channel number) to the binary number.

Example: Channel number14 (master 1 and slave 4)=23 + 22+ 21. Set C3, C2 and C1 to "Lo".

In other words 14=26 x 0 + 25 x 0 + 24 x 0 + 23 x 1 + 22 x 1 + 21 x 1 + 20 x 0

Therefore you will get C6=Hi, C5=Hi, C4=Hi, C3=Lo, C2=Lo, C1=Lo, C0=Hi