COMMAND

PARAMETER

(min/max)

Value stored?

DESCRIPTION

!STORE

NA

YES

Stores the current set of values
(all values) into non-volatile
memory

!RESTORE

NA

YES

Restores the stored values

!FACTORY

NA

YES

Restores all values to factory
default levels

!STATUS

NA

NA

Asks the Controller to provide
the hardware information,
current values and system status
to the automation system

!RESTART

NA

NO

Restarts the Controller
(same as turning it on and off)

!ECHO

NA

NO

Enables the Controller to echo
back commands and values to
the automation system

!NOECHO

NA

NO

Disables the Controller's
character echoing

!INSTALLMODEOFF

NA

NA

Disables the Installation menu
(removes it from the main menu)

!INSTALLMODEON

NA

NA

Enables the Installation menu
(enables it on the main menu)

5