Prog (p. 150), 150 chapter 8 parameter guide system – Roland V-Bass VB-99 User Manual

Page 150

Advertising
background image

150

Chapter 8 Parameter Guide SYSTEM

Parameter/
Range

Explanation

PC (Program Change)
PC OUT (Program Change Out)

OFF, ON

This setting determines whether or not Pro-
gram Change messages are output when the
VB-99’s patches are switched.
Program Change messages are output when
this is set to ON.

TX PC MAP (Transmit Program Change Map)

This setting determines the sequence of Program Change messages
output when the VB-99’s patches are changed.

FIX

Regardless of the patch settings, Program
Change messages predetermined for each
patch number are output.

PROG

The Program Change messages pro-
grammed in each patch are output.

RX PC MAP (Receive Program Change Map)

You can select whether to use a fixed or freely set correspondence be-
tween program numbers received and the patches switched to when
the VB-99’s patches are switched by Program Change messages
transmitted by an external MIDI device.

FIX

The VB-99 switches to the patches predeter-
mined for the corresponding received Pro-
gram Change messages, regardless of the
Receive Program Change Map settings.

PROG

The VB-99’s switches to the patches set in
the Receive Program Change Map.

RX PC MAP (Receive Program Change Map)

You can edit the correspondence between the Program Change num-
bers received and the patches that are switched to.

[F1] (BANK)

Selects the Bank number.

[F2] [F3] (SEL)/
F2, F3 knob

Selects the Program number.

[F5] (SELECT)/
F5 knob

Selects the patch.
When the combination of the Bank number
and Program number selected with F1, F2,
and F3 is received, the VB-99 switches to the
patch selected with F5.

TX CC (

Transmit

Control Change)

This sets the Control Change numbers output when the VB-99’s ped-
als and external pedals or the FC-300’s pedals and external pedals
are operated.

[F2] [F3] (SEL)/
F2, F3 knob

Selects the controller.

[F5] (SET OFF)/
F5 knob

When the controller selected with F2 or F3 is
operated, the Control Change message se-
lected with F5 is transmitted.

Parameter/
Range

Explanation

BULK DUMP

With the VB-99, you can use Exclusive messages to set another VB-
99 to the same settings or to save effect sound settings to MIDI se-
quencers and other such devices.

ALL

All transmittable data (SYSTEM, GK SET-
TING, GLOBAL, PATCH 001–200, FAVOR-
ITE SETTING)

SYSTEM

SYSTEM parameters.

GK SETTING

Settings content for GK SETTING

GLOBAL

GLOBAL function settings

PATCH

Settings for patch numbers 001–200

FAVORITE SETTING

Settings content in FAVORITE SETTINGS
01–10 for all effects

VB-99_e.book 150 ページ 2008年8月18日 月曜日 午後1時10分

Advertising