Appendix b, Appendix – Rockwell SoniCrafter DEVICENET 1771-SDN User Manual

Page 115

Advertising
background image

1

Publication 1771-6.5.132 - June 2000

Appendix

B

Installing and Configuring the ControlNet
Communications Driver

The examples using ControlNet in this manual were performed with a
1784-KTCX15 communication interface card installed in the personal
computer that was used as a programming terminal. This appendix
describes how to install and configure the 1784-KTCX15 card.

Installing the 1784-KTCX15
Communication Interface
Card

Perform the following steps to install the 1784-KTCX15 card in your
personal computer.

1. Set the card’s base memory address location on switches S1 and S2.

2. Set the card’s base I/O space address location on switch S3.

For detailed information on
installing the 1784-KTCX15, refer
to the ControlNet Communication
Interface Card Installation
Instructions, publication number
1784-5.33.

More

D000:0000

Front of Switches

Factory-set address
(recommended setting)

up (1)

S2

S1

down (0)

Front View

Side View

down (0)

up (1)

Front View

Side View

down (0)

up (1)

up (1)

down (0)

S3

240h shown

(adjust for your system)

Front of Switches

Advertising