Settings for digital connections, Sampling clock source, Sampling frequency – Roland MMP-2 User Manual

Page 26: Audio input source, Display messages

Advertising
background image

26

Settings for Digital Connections

When you change the digital-connection settings, sound may stop momentarily until the
new settings are in place.

Sampling Clock Source

Select the source of sampling clock.

fig.LcdClock.eps

1.

Press the [SYSTEM] button several times to display “CLOCK.” The button lights
up in green.

2.

Turn the left Value control to make the selection.
“INT”:

Uses the internal clock.

“DIGI”:

Synchronizes with the clock signal from [DIGITAL IN].

Sampling Frequency

Set frequency of internal clock (INT). Four are supported: 44.1k Hz, 48.0k Hz, 88.2k Hz, and 96.0k Hz.

* In case the sampling clock source (CLOCK) is supplied from external devices (DIGI), it is impossible to set

sampling frequency on MMP-2.

fig.LcdClock.eps

1.

Press the [SYSTEM] button several times to display “FREQ.” The button lights
up in green.

2.

Turn the center Value control to make the selection.

Audio Input Source

Select the jacks to input.

fig.LcdClock.eps

1.

Press the [SYSTEM] button several times to display “AUDIO.” The button lights
up in green.

2.

Turn the right Value control to make the selection.
“MIC”:

Input from [MIC IN]

“DIGI”:

Input from [DIGITAL IN]

* When you change the input source, sound may stop momentarily until the changeover has been completed.
* There is no need to make settings for the output. Outputs include the [LINE OUT], [AES/EBU],

and [DIGITAL OUT] jacks.

* “AUDIO: DIGI” and “CLOCK: INT” cannot be selected simultaneously.

Relation of each setting is shown on the chart below.

Display Messages

CLOCK (sampling clock source)

INT

DIGI

FREQ (sampling frequency)

44.1k/48.0k/88.2k/96.0k

synchronizes with [DIGITAL IN]

AUDIO (audio input source)

MIC

MIC / DIGI

Digital In locked.

Changed the source of Sampling Clock to [DIGITAL IN].

Wrong sample freq.

A digital signal that is not compatible with MMP-2 is coming in from [DIGITAL IN].
The following causes can be considered.
• Sampling frequency of inputting device is not one of followings;

44.1k Hz, 48.0k Hz, 88.2k Hz or 96.0k Hz

• Vari-pitch (function to change sampling frequency continuously) is

used on inputting devices.

DIGITAL IN checking...

Confirming signal from [DIGITAL IN].

DIGITAL IN unlock!
Change INTERNAL?

The signal compatible with MMP-2 is not coming in. The system waits for the sig-
nal. Do you cancel the Digital Input and return to internal clock?

Advertising