Installation, Unit assembly prior to installation, Top flue collar installation – Regency Bellavista Gas Fireplace B36X User Manual

Page 15

Advertising
background image

Regency Bellavista™ B36X Gas Fireplace

15

INSTALLATION

TOP FLUE COLLAR INSTALLATION

Note: This conversion must be done prior to the unit being placed in position.

The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.

Top Collar Assembly Kit

1

Intake Collar Assembly with Gasket

1

Intake Collar Plate with Gasket

1

Top/Rear Exhaust Assembly with Gasket

1

Heat Defl ector

1

Baffl e Plate

29

1/4" x 1/2" Screws (4 spares)

1

Restrictor

1

Intake Collar Gasket (spare)

1

Exhaust Assembly Gasket (spare)

Exhaust Assembly

w/ gasket

Intake Collar Plate

w/gasket

Intake Collar Assembly

w/gasket

2) From inside the fi rebox, remove the top heat defl ector by removing

2 - 1/4" x 1/2" screws.

Heat Defl ector

Diagram 2

1. Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly.

Adjustable Tension

Latch location

Diagram 1

3) From inside the fi rebox, remove the baffl e plate by removing 4 - 1/4"

x 1/2 " screws. See Diagram 3

Baffl e Plate

Diagram 3

4) From the inside of the fi rebox, remove the exhaust assembly by

removing the 8 - 1/4" x 1/2" screws. See Diagram 4.

Diagram 4

UNIT ASSEMBLY PRIOR TO INSTALLATION