Installation – Regency Bellavista Gas Fireplace B36X User Manual

Page 25

Advertising
background image

Regency Bellavista™ B36X Gas Fireplace

25

INSTALLATION

Rigid Pipe Adaptor

Pipe Length

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

Vinyl Siding

Standoff (Optional)

Rigid Pipe Adaptor

Pipe Length

Horizontal

Termination

Cap

Wall Thimble

Vinyl Siding

Standoff (Optional)

Horizontal Termination

A

Top Vent - No Vertical Rise
• When venting with a 90° elbow directly
off the unit, must use 5" X 8" Astrocap™
Flex vent or approved Rigid Vent System
• Max. 3 ft. horizontal run

B

Rear Vent w/ Horizontal Termination
• Can only use 5" x 8" venting
• Max. 3ft. horizontal run

B

A

HORIZONTAL TERMINATIONS

RIGID PIPE VENTING ARRANGEMENTS (5" X 8")

The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.

For horizontal terminations the Regency Direct Vent Flex System (see page 14) may be used for installations with a maximum continuous vent length of
3ft (0.9m).

Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.

• Maintain clearance to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.

2

0

12

6

4

8

10

2

0

6

4

8

V

ertical

Height

(Feet)

Rigid

44-1/4"(1.1m)

Horizontal (Feet)

Max. 36”(0.9m)

Flex

42-1/8"(1.0m)

Factory Setting - No Restrictor Required

Factory Setting - No Restrictor Required