AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

Minimum Air Shutter Opening:

NG 1/16"

LP 1/4"

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat
will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan
is installed at a later date.

Ground

Green

Neutral

Live

Black

Red

Red

Minimum Convection

Air Temp. Switch

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

Piezo

Ignitor

To Thermocouple IN

Pilot

Assembly

H

I

LO

OFF

ON

P

IL

O

T

Gas

Pilot

Thermopile

Thermocouple

Electrode

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(mobile home

approved)

Star washer

Remote Transmitter

(Optional)

ON

OFF

Regency

Remote Receiver

or Thermostat

(Millivolt) (Optional)

Brown

White

Black

White

"S.I.T" Valve

Burner ON

OFF

(To THTP)

(To TH)

(To TH)

White

Gas
In

Optional Fan # 576-917

For

NATURAL GAS

Units and Units

NOT

Equipped with DC Spark Boxes

Air shutter rod - located to the left
of the valve assembly.

Advertising