Installation, Dc sparker installation, Dc sparker battery replacement – Regency Bellavista Gas Fireplace B36X User Manual

Page 42: Installation of the dc sparker

Advertising
background image

42

Regency Bellavista™ B36X Gas Fireplace

INSTALLATION

DC Sparker Battery Replacement

23)

Locate the Piezo Ignitor situated at the right side of the

valve assembly.

24)

Remove the Piezo Ignitor wire from the back of the Piezo Ignitor.

25)

Connect the ignitor wire from the Piezo to the DC sparker.

1)

Remove the battery cover from the DC Sparker - remove the AA
battery.

2)

Replace with a new 'AA' battery and reinstall battery cover.

Piezo

Ignitor

Ignitor

Wire

Piezo

Ignitor

Ignitor

Wire

DC

Sparker

DC Sparker

Generator Wires

26)

Connect the DC spark generator wires to the SIT Valve.

Secure with a phillips head screw as shown below.

27)

Plug the DC spark generator wires to the DC Sparker.

28)

Remove the battery cover from the DC Sparker and install 1 -

'AA' battery in the DC Sparker and then install the DC Sparker to
the fl oor of the unit, left of the valve assembly, with two Phillips
screws.

Installation of the DC Sparker:

DC SPARKER INSTALLATION