Installation, Venting arrangements, Allowable vertical terminations – Regency Bellavista Gas Fireplace B36X User Manual

Page 28: 4" x 6 - 5/8" pipe venting arrangements, 28 regency bellavista™ b36x gas fireplace, Elbows equal to one 90, Elbow. maximum of four 45

Advertising
background image

28

Regency Bellavista™ B36X Gas Fireplace

INSTALLATION

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS

(MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994)

4" X 6 - 5/8" PIPE VENTING ARRANGEMENTS

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90

o

elbows, with Rigid Pipe

Venting Systems for Propane and Natural Gas. Two 45

o

elbows equal to one 90

o

elbow. Maximum of four 45

o

elbows allowed.

Note: The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor.
Only rigid pipe may be used when 4" x 6-5/8" is ever used.

• Vent must be supported at offsets.
• Firestops are required at each fl oor level and whenever passing through a wall.
• Maintain clearances to combustibles as listed in the "Clearances" section.

Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting
to 2" opening to 1" opening.

Note: Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994).

Maximum:

35.5

ft.

(10.

m)

8

Minimum

8’

(2.4m)

Min.

49”

(1.2m)

Max. 10’ (3m)(centerline to centerline)

Maximum:

1

9

ft.

(5.8m)

0

2

4

6

40

8

10

12

14

16

18

20

22

24

26

28

30

V

ertical

Height

(Feet)

32

34

36

38

6

8

Horizontal (Feet)

2

0

4

10

12

16

18

18

14

Restrictor 1” Open

Restrictor 2” Open

Maximum 12’ Centerline to Centerline

Advertising
This manual is related to the following products: