1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label) after burning
appliance for 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.

LOCATING YOUR

GAS FIREPLACE

B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

Diagram 1

1) When selecting a location for your fi replace,

ensure that the clearances are met.

2) The appliance must be installed on a fl at, solid,

continuous surface For example a wood, metal
or concrete fl oor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.

3) The B36X Bellavista™ Gas Fireplace can be

installed in a recessed position or framed out
into the room as in A, B, C and D. See Diagram
1.

A) Flat on Wall

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your Gas

fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantel Clearances (Refer to "Combustible

Mantel Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top Standoffs and Top Facing

Support and Side Nailing Strips (Refer to "Unit
Assembly Prior to Installation" Section). NOTE:
Must be done before installing unit into place.

3) Install vent (Refer to "Venting" sections).

4) Make gas and electrical connections. Test the

pilot. Must be as per diagram (Refer to "Pilot
Adjustment " section).

Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from NG
to LPG" sections).

5) Install standard and optional features. Refer

to the following sections:


a. LP Conversion Kit (Optional)

b. Brick Panels (Optional)

c. Log Set Installation

d. Standard Flush Door

e. Full Screen Door (Optional)

f. Flush Panel/Louver (Optional)

g. Remote control,Wall Switch or
Thermostat (Optional)

h . F a n I n s t a l l a t i o n ( O p t i o n a l )

6) Final

check.

4) This appliance is Listed for bedroom installations

using the standard Remote (millivolt thermostat
system). Some areas may have further
requirements, check local codes before
installation.

5) The B36X Gas Fireplace are approved for

alcove installations, see "Clearances" section
for details.

6) We recommend that you plan your installation on

paper using exact measurements for clearances
and fl oor protection before actually installing
this appliance. Have an authorized inspector,
dealer, or installer review your plans before
installation.

Note: For vent terminations refer to "Exterior

Vent Termination Locations" section.

HEATWAVE

DUCT SYSTEM

(OPTIONAL)

#946-556

The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing warm
air from the fi replace to remote locations in the
same room or other rooms in your home.

Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be oper-
ated at one time. This includes the internal blower
option as well.