Regency Bellavista™ B36X Gas Fireplace

29

INSTALLATION

HORIZONTAL VENTING WITH TWO (2) 90

O

ELBOWS

(RIGID PIPE 4" X 6 - 5/8")

16

2

2

0

0

12

12

6

6

18

18

4

49"
(1245mm)
Minimum
Height
Requirement

4

14

8

8

10

10

14

16

18

18

20

V

ertical

Height

(Feet)

Horizontal (Feet)

Restrictor 1” Open

Restrictor 2” Open

VENTING ARRANGEMENTS HORIZONTAL TERMINATION

(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)

(RIGID PIPE 4" X 6-5/8")

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90

o

two 45

o

elbows equal one 90

o

elbow).

• Maintain clearances to combustibles

as listed in "Clearances" section

• Horizontal vent must be supported

every 3 feet.

• Firestops are required at each fl oor

level and whenever passing through a
wall.

• A wall thimble is mandatory for all

horizontal terminations due to high
temperatures.

ALL RIGID PIPE SYSTEMS

4" INNER DIAMETER

6-5/8" OUTER DIAMETER

H

H1

V

Lengths do not include elbow indicated.
Must use reducer # 946-606 and rigid pipe adaptor #770-994.

Option V

H + H1

A)

0' Min. 2' Max.

B)

1' Min. 3' Max.

C)

2' Min. 4' Max.

D)

3' Min. 5' Max.

E)

4' Min. 6' Max.

F)

5' Min. 7' Max.

G)

6' Min.

77''7'

W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90

o

elbows

is required.

One 90

o

elbow = Two 45

o

elbows.

Vent Restrictor Set at 2" Opening

8' Max.