Installation, Rigid pipe venting systems, Horizontal or vertical terminations – Regency Bellavista Gas Fireplace B36X User Manual

Page 26

Advertising
background image

26

Regency Bellavista™ B36X Gas Fireplace

INSTALLATION

Pipe Length

Vertical

Termination

Cap

Storm Collar

Flashing

Ceiling Firestop

Rigid Pipe Adaptor

Pipe

Length

Pipe Length

90 Elbow

o

Astrocap

(946-523/P)

Wall Thimble

Vinyl Siding

Standoff (Optional)

Reducer

(4” x 6-5/8” venting)

43”

(1092 mm)

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination using 4" x 6-5/8" are:

1 Rigid

Pipe

Adaptor

1 Reducer
1 90

o

Elbow

1 Wall

Thimble

1 Length of pipe to suit wall thickness
1 Horizontal Termination Cap

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may
be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding.
Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent,

American Metal Products, Security Secure Vent

®

, AmeriVent Direct Vent. AstroCap

TM

is the proprietary trademark of FPI Fireplace Products International

Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
DuraVent Direct Vent, Selkirk Direct-Temp, Ameri
Vent Direct venting and Security Secure Vent
systems. Use of these systems with the Rigid
Pipe Adaptor is deemed acceptable and does not
affect the Intertek WHI listing of components.

WARNING:

Do not combine venting components from
different venting systems.

Exception: However, use of the AstroCap

TM

and

FPI Riser is acceptable with all systems.

A

B

11”

(279mm)

11”

(279mm)

ASTROCAP # 946-523/P

DIMENSIONS