Regency Bellavista™ B36X Gas Fireplace

INSTALLATION

HORIZONTAL TERMINATIONS

REGENCY

®

DIRECT VENT FLEX SYSTEM (5" X 8")

These venting systems, in combination with the B36X Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey.
The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.

Regency

®

Direct Vent (Flex) System 4 foot

Termination Kit (Part# 946-615) includes all
the parts needed to install the B36X with a
either a top or rear vent.

1) 8"

dia.

fl exible liner (4 ft. length)

2) 5"

dia.

fl exible liner (4 ft. length)

3) spring spacers (4)
4) thimble
5) AstroCapXL termination cap (1)
6) screws

(12)

7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,

Stainless Steel (4)

10) vinyl siding standoff

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from FPI may be used for Flex installations.

Note: If longer runs are required - rigid pipe must be used.