SECTION 15: S

ERVICING

I

NSTRUCTIONS

63 of 75

Tubes

Make sure there are no cracks.

Make sure tubes are connected and suspended securely.

See Page 11, Section 5.

Make sure there is no sagging, bending or distortion.

Gas Line

Check for gas leaks.

See Page 53, Section 12.

Burner Observation
Window

Make sure it is clean and free of cracks or holes.

Clean and replace as required.

Blower Scroll, Wheel and
Motor

Compressed air or a vacuum cleaner may be used to clean dust and dirt.

Burner Cup and Orifice

Clear of obstructions (even spider webs will cause problems).
Carefully remove any dust and debris from the burner.

Electrode

Replace if there are cracked ceramics, excessive carbon residue, or erosion
of the electrode.

The electrode gap should be 3 mm.

Thermostat

There should be no exposed wire or damage to the thermostat.

See Page 55, Section 13.

Suspension Points

Make sure the heater is hanging securely.

Look for signs of wear on the chain or ceiling.

See Page 11, Section 5.

Sports Hall Guard,
Decorative and Protective
Grilles (optional)

The grille must be securely attached. If the grille is loose or off, contact a
contractor qualified in the installation and service of gas-fired heating equip-
ment for repair.

Check that side reflector extensions are installed correctly and secured in
place if necessary (decorative grille only).

See Page 42, Section 10.1 and Page 45, Section 10.4.

Make sure shield is installed correctly and secured in place if necessary.
(Decorative grille only.)

See Page 44, Section 10.3.2.

Wall Tag

If a wall tag is present, make sure it is legible and accurate. Please contact
Roberts-Gordon LLC or your ROBERTS GORDON

®

independent distributor

if you need a wall tag.

See Page 4, Section 2.1.