Through section 18.8 – Roberts Gorden Vacuum Assisted Linear User Manual

Page 79

Advertising
background image

SECTION 18: S

PECIFICATIONS

73 of 75

* Only available in Multiburner.

18.6 Linear Heater

BH

15

ST

BH

20

ST

BH

25

ST

BH

25

ST

/EF

BH

30

ST

BH

30

ST

/EF

BH

35

ST

BH

35

ST

/EF

BH

40

ST

BH

40

ST

/EF

BH

45

ST

BH

45

ST

/EF

BH

50

ST

BH

50

ST

/EF

BH

55

ST

*

Input - Gross (kW)

15

20

25

30

35

40

45

50/51

55

Input - Net (kW)

13.5

18

22.5

27

31.5

36

40.5

45/46

49.5

Tube Length (mm)

6096

9144

9144

12192

12192

12192

15240

15240

18288

Overall Heater Length (mm)

6661

9709

9709

12757

12767

12767

15815

15850

18579

Weight (kg)

39

55

55

68

68

68

81

81

95

Heated Area (m

2

)

20-160

30-210

40-265

50-315

55-370

65-420

70-475

80-525

90-620

Minimum Installation
Height(mm)

3500

3500

3500

3500

4600

5000

5000

5000

6000

Recommended Installation
Height (mm)

3500

3600

3900

4200

4800

5500

6700

7600

8000

18.7 Double Linear Heater

BH

30

DL

BH

40

DL

BH

50

DL

BH50

DL

/EF

BH

60

DL

BH60

DL

/EF

BH

70

DL

BH70

DL

/EF

Input - Gross (kW)

30

40

50

60

70

Input - Net (kW)

27.5

36

45

54

63

Tube Length (mm)

12802

18898

18898

24994

24994

Overall Heater Length (mm)

13462

19558

19558

25654

25654

Weight (kg)

82

110

110

136

136

Heated Area (m

2

)

50-315

65-420

80-525

100-630

110-740

Minimum Installation Height (mm)

3500

3500

3500

3500

4600

Recommended Installation Height

(mm)

3500

3600

3900

4200

4800

18.8 U-Tube Heater

BH

1

5

U

T

BH

2

0

U

T

BH

2

5

U

T

BH

2

5

U

T

/EF

BH

3

0

U

T

BH

3

0

U

T

/EF

BH

3

5

U

T

BH

3

5

U

T

/EF

BH

4

0

U

T

BH

4

0

U

T

/EF

BH

4

5

U

T

BH

4

5

U

T

/EF

BH

5

0

U

T

BH

5

0

U

T

/EF

Input - Gross (kW)

15

20

25

30

35

40

45

50

Input - Net (kW)

13.5

18

22.5

27

31.5

36

40.5

45

Tube Length (mm)

3531

5055

5055

6579

6579

6579

8103

8103

Overall Heater Length (mm)

3822

5346

5346

6870

6870

6870

8394

8394

Weight (kg)

41

54

54

65

65

66

96

96

Heated Area (m

2

)

20-160

30-210

40-265

50-315

55-370

65-420

70-475

80-525

Minimum Installation Height (mm)

3500

3500

4000

4700

5000

5000

5000

5000

Recommended Installation Height (

mm

)

3500

3600

4000

4700

5000

5500

6700

7600

Advertising