Pre l iminar y – Runco LIGHTSTYLE LS-10I User Manual

Page 89

Advertising
background image

Maintenance and Troubleshooting

Runco LS-10i Installation/Operation Manual

73

PRE

L

IMINAR

Y

Image appears “washed out”
and/or dark areas appear too
bright.

• Brightness is set too high.

• Lower the brightness

setting.

Colors in the image are
swapped; for example, reds
appear blue or vice versa.

• The Red/Pr, Green/Y or

Blue/Pb outputs from the
source are connected to
the wrong inputs on the
LS-10i.

• Ensure that the source

outputs are connected to
the correct LS-10i input.

LED is flashing alternating
green and red.

• The lamp cover is open.
• The lamp has failed or

exceeded its usage life.

• Close the lamp cover.
• Replace the lamp with a

new one.

LED is flashing red.

• LS-10i internal

temperature is too high.

• Power off the LS-10i and

allow it to cool down.
Ensure that the intake and
exhaust vents are not
blocked. Turn the
projector back on. If the
problem persists, please
contact Runco Technical
Support for assistance.

LED lights solid red.

• Fans are not working

properly or power-on
self-test has failed (Note).

• Please contact Runco

Technical Support for
assistance.

Table 5-1. Troubleshooting Chart (continued)

Symptom

Possible Cause(s)

Solution

Note: You can obtain more detailed information about the cause of the error condition using
RS-232 commands. Refer to RS-232 Error Codes on page 86 for more information.