Dynamixel dx-series, 2. instruction packet, 3. status packet – Robotis Dynamixel DX-117 User Manual

Page 10

Advertising
background image

9

DYNAMIXEL

DX-Series

3-2. Instruction Packet

The structure of the Instruction Packet is as follows:

Instruction Packet

OXFF 0XFF ID LENGTH INSTRUCTION PARAMETER1 …PARAMETER N CHECK

SUM

The packet byte definitions are as follows.

0XFF 0XFF

Two 0XFF bytes indicate the start of an incoming packet.

ID

Unique ID of a Dynamixel. The ID can range from 0X00 to 0XFD (254 IDs are available)

Broadcasting ID

ID ID 0XFE is the Broadcast ID which is assigned to all of the connected Dynamixel’s.

Status packets will not be returned with a broadcasting ID.

LENGTH

The length of the Status Packet. The value is “Parameter number (N) + 2”

INSTRUCTION

The instruction for the Dynamixel to perform.

PARAMETER0…N

Used if there is additional information to be sent other than the Instruction.

CHECK SUM

The calculation method for the ‘Check Sum’ is as follows:

Check Sum = ~( ID + Length + Instruction + Parameter1 + … Parameter N )

If the calculated value is bigger than 255, the lower byte becomes the checksum.

~ represents the Not or complement operation

3-3. Status Packet

The Status Packet is the response packet from the Dynamixel to the Main Controller

after receiving an instruction packet. The structure of Status Packet is as follows :

OXFF 0XFF ID LENGTH ERROR PARAMETER1 PARAMETER2…PARAMETER N

CHECK SUM

The meaning of each byte within the packet is as follows :