Dynamixel dx-series – Robotis Dynamixel DX-117 User Manual

Page 28

Advertising
background image

27

DYNAMIXEL

DX-Series

Example 20

Prevent the Dynamixel with ID=0 from changing values other than within the range

between Address 0x18 and Address 0x23.

Set Address 0x2F(Lock) to 1.



Instruction Packet
Instruction = WRITE_DATA, Address = 0x2F, DATA = 0x01

Communication

->[Dynamixel]:FF FF 00 04 03 2F 01 C8 (LEN:008)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR

If Locked, it can only be unlocked by removing power.

If trying to access other data areas whilst locked, an error will be returned.


->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)

<-[Dynamixel]:FF FF 00 02 08 F5 (LEN:006)

Example 21

Set the minimum punch (output) in the Dynamixel with ID=0 to 0x40.


Instruction Packet
Instruction = WRITE_DATA, Address = 0x30, DATA = 0x40, 0x00

Communication

->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR

Range Error