The direction of data signals on the TTL level TxD and RxD depends on the

DIRECTION485 level as the following.

• When the DIRECTION485 level is High: the TxD signal is outputted as D+, D-

• When the DIRECTION485 level is Low: the D+, D- signal is inputted to RxD

RS485

The communication protocol used by the Dynamixel actuator, RS485 (IEEE485), uses

the multi-drop method of connecting multiple terminals on a single node. Thus a protocol

that does not allow multiple transmissions at the same time should be maintained on a

RS485 network.

Note

Please ensure that the pin assignments are correct when connecting the Dynamixel

actuators. Check the current consumption after the wiring is completed. The current

consumption of a single Dynamixel actuator unit in standby mode should be no larger

than 50mA.

Connection Status Verification

When power is applied to the Dynamixel actuator, the LED blinks twice to confirm its

connection.

Inspection

If the above operation was not successful, check the connector pin assignment and the

voltage/current limit of the power supply.

Main

Controller

[RS485 Multi Drop Link]