Instruction set and examples, Dynamixel dx-series, 1. write_data – Robotis Dynamixel DX-117 User Manual

Page 19

Advertising
background image

18

DYNAMIXEL

DX-Series

4. Instruction Set and Examples

The following Instructions are available.

4-1. WRITE_DATA

Function

Write data into the control table of the Dynamixel

Length

N+3 (Writing Data is N)

Instruction

0X03

Parameter1

Start Address of the Area to write Data

Parameter2

1st Data to write

Parameter3

2nd Data to write

Parameter N+1

Nth Data to write

Example 1

Set ID of connected Dynamixel as 1

Write 1 into the Address 3 of the Control Table. The ID is transmitted using Broadcasting

ID (0xFE).

Instruction

Function

Value

Num ber of
Parameter

PING

No action. Used to obtain a Dynam ixel Status
Packet.

0x01

0

READ DATA

Read the values in the Control table.

0x02

2

W RITE DATA

W rite the values to the Control Table.

0x03

2 ~

REG W RITE

Sim ilar to W RITE DATA, but stay in standby
m ode until write upon the action instruction.

0x04

2 ~

ACTION

Start the action registered by REG W RITE.

0x05

0

RESET

Change the values of the Dynam ixel in the
control table back to the Factory Default Values

0x06

0

Advertising