5. Example

Used to explain through example with the assumption that the Dynamixel has been

Reset (ID = 1, Baudrate = 57142BPS)

Example 6

Read the Model Number and Firmware Version of a Dynamixel with ID=1


Instruction Packet Instruction = READ_DATA, Address = 0x00, Length = 0x03

Communication

->[Dynamixel]:FF FF 01 04 02 00 03 F5 (LEN:008)

<-[Dynamixel]:FF FF 01 05 00 74 00 08 7D (LEN:009)


Status Packet Result
Model Number = 116(0x74), Firmware Version = 0x08

Example 7

Change ID number of Dynamixel from 1 to 0.


Instruction Packet Instruction = WRITE_DATA, Address = 0x03, DATA = 0x00

Communication

->[Dynamixel]:FF FF 01 04 03 03 00 F4 (LEN:008)

<-[Dynamixel]:FF FF 01 02 00 FC (LEN:006)

Status Packet Result NO

ERROR

Example 8

Change Baud Rate of Dynamixel to 1M bps.



Instruction Packet Instruction = WRITE_DATA, Address = 0x04, DATA = 0x01

Communication

->[Dynamixel]:FF FF 00 04 03 04 01 F3 (LEN:008)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR