Example 3

To obtain the status packet of a Dynamixel with ID=1

Instruction Packet : 0XFF 0XFF 0X01 0X02 0X01 0XFB`

ID LENGTH INSTRUCTION CHECKSUM

The returned Status Packet is as follow;

Status Packet : 0XFF 0XFF 0X01 0X02 0X00 0XFC

ID LENGTH ERROR CHECKSUM



4-5. RESET

Function

Restore the condition of the Control Table of the Dynamixel back to the Factory Default

values.

Length

0X02

Instruction

0X06

Parameter

NONE

Example 4

Reset Dynamixe with ID=0

Instruction Packet : 0XFF 0XFF 0X00 0X02 0X06 0XF7`

ID LENGTH INSTRUCTION CHECKSUM

The returned Status Packet is as follows;

Status Packet : 0XFF 0XFF 0X00 0X02 0X00 0XFD

ID LENGTH ERROR CHECKSUM

Please note that after a RESET instruction, the ID of the Dynamixel is changed to 1.