Dynamixel dx-series, 2. read_data, 3. reg_write and action – Robotis Dynamixel DX-117 User Manual

Page 20: 3-1. reg_write

Advertising
background image

19

DYNAMIXEL

DX-Series

Instruction Packet : 0XFF 0XFF 0XFE 0X04 0X03 0X03 0X01 0XF6

ID LENGTH INSTRUCTION PARAMETERS CHECKSUM

Because it was transmitted by Broadcast ID(0XFE), no return status packet.


4-2. READ_DATA

Function

Read data from the Control Table of Dynamixel

Length

0X04

Instruction

0X02

Parameter1

Starting Address of Data to Read

Parameter2

length of Data to Read

Example 2

Read the internal temperature of the Dynamixel with ID=1

Read 1 byte from the Address 0x2B values of the Control Table

Instruction Packet : 0XFF 0XFF 0X01 0X04 0X02 0X2B 0X01 0XCC`

ID LENGTH INSTRUCTION PARAMETERS .. CHECKSUM

The returned Status Packet will be as follows

Status Packet : 0XFF 0XFF 0X01 0X03 0X00 0X20 0XDB

ID LENGTH ERROR PARAMETER1 CHECKSUM

The value read is 0x20.The current Dynamixel’s internal temperature is approximately 32 (0X20).

4-3. REG_WRITE and ACTION


4-3-1. REG_WRITE