0XFF 0XFF

Two 0XFF bytes indicate the start of a packet.

ID

ID of the Dynamixel which is returning the packet.

LENGTH

The length of the Status Packet. The value is “Parameter number (N) + 2”.

ERROR

Dynamixel communication error flags. The meaning of each bit is as follows:

PARAMETER0…N

Used when additional information is required.

CHECK SUM

SUM Calculation method of ‘Check Sum’is as follows:

Check Sum = ~( ID + Length + Instruction + Parameter1 + … Parameter N )

If the calculated value is bigger than 255, the lower byte becomes the checksum.

~ represents the Not or complement operation

Bit

Name

Details

Bit 7

0

-

Bit 6

Instruction Error

Set to 1 if an undefined instruction is given without the
reg_write instruction.

Bit 5

Overload Error Set to 1 if the specified torque can't control the load.

Bit 4

Checksum Error

Set to 1 if the checksum of the intruction packet is
incorrect

Bit 3

Range Error

Set to 1 if the instruction is out of the usage range.

Bit 2

Overheating

Error

Set as 1 if the internal temperature of Dynamixel is out of
the operative range as set in the control table.

Bit 1

Angle Limit Error

Set as 1 if the goal position is set outside of the range
between CW Angle Limit and CCW Angle Limit

Bit 0

Input Voltage

Error

Set to 1 if the voltage is out of the operative range set in
the control table.

Advertising