Dynamixel dx-series – Robotis Dynamixel DX-117 User Manual

Page 17

Advertising
background image

16

DYNAMIXEL

DX-Series

Address 0x20,0x21

Moving Speed. The angular speed to move to the Goal Position. If set to the maximum

values of 0x3ff, it moves at 70RPM.

Address 0x24,0x25

Present Position. Current position of the Dynamixel.

Address 0x26,0x27

Present Speed. Current Speed of the Dynamixel

Address 0x28,0x29

Present Load. Load size on the Dynamixel in action. Bit 10 is the direction of the load.

Load Direction = 0 : CCW Load, Load Direction = 1: CW Load

Address 0x2A

Present Voltage. The voltage applied to the Dynamixel. The value is 10 times the actual

voltage. For example, 10V is read as 100(0x64).

Address 0x2B

Present Temperature. Current internal Dynamixel temperature (Degrees Celsius).

Address 0x2C

Registered Instruction. Set to 1 when a REG_WRITE instruction is made. After an

Action instruction and an action it is reset to 0.

Address 0x2E

Moving. Set to 1 when the Dynamixel moves by its own power.

Address 0x2F

Lock. If set to 1, only Address 0x18 ~ Address 0x23 can be written to. Other areas are

not permitted. Once locked, it can only be unlocked by powering down.

Address 0x30,0x31

Punch. Minimum current being supplied to the motor during an action. The minimum

value is 0x20 and the maximum value as 0x3ff.

BIT

15~11

10

9

8

7

6

5

4

3

2

1

0

Value

0

Load Direction

Load Value

Advertising
This manual is related to the following products: