Using Socket Services by Manipulating Dedicated Control Bits

Section 6-7

Basic Operations

• CIO 000000 is turned ON to request opening a UDP socket from the

Ethernet Unit.

• CIO 000001 is turned ON to request closing the UDP socket from the

Ethernet Unit.

• CIO 000002 is turned ON to request sending data from the Ethernet Unit.

The data is sent (100 bytes) beginning from word D00000.

• CIO 000003 is turned ON to request receiving data from the Ethernet

Unit. The data that is received (100 bytes) is stored beginning at D01000.

• One of the bits between CIO 000100 and CIO 000103 will turn ON if an

error occurs. Refer to 6-7-5 Socket Service Request Switches for informa-
tion on errors.

Program Memory Map

The send and receive data and bits (flags) used by the program are shown in
the following diagram.

DM Area

CIO Area

Send data, 100 bytes (100 = 0064 Hex)

Receive data, 100 bytes (100 = 0064 Hex)

7

6

5

4

3

2

1

0

CIO 0000

CIO 0001

15 to 8

CIO 0002

UDP
Send
Bit

UDP
Close
Bit

UDP
Open
Bit

UDP
Receive

Error
Flag

UDP
Send
Error
Flag

UDP
Close
Error
Flag

UDP
Open
Error
Flag

UDP
Receiving
Flag

UDP
Sending
Flag

UDP
Closing
Flag

UDP
Opening
Flag

UDP
Receive
Bit