20

Using the Mail Send Function

Section 2-4

Note

(1) Make POP settings when the Use POP before SMTP Option was select-

ed in the SMTP Tab.

(2) Make DNS settings when the Server specification type is set to Host

name in the SMTP or POP Tab.

Send Mail
(Send mail
conditions 1 to
8)

Trigger type

One type must be selected.

• Rising edge of the Mail Send Switch: Select the Software

switch Option.

• Change in specified word's value: Select the Word value

change Option and specify the Area, Address, Value, and
State.

• Change in specified bit's status: Select the Bit value change

Option and specify the Area, Address, Bit, and State.

• Entry in Ethernet Unit's error log: Select the ETN condition

Option.

• Change in CPU Unit status: Select the CPU condition Option.
• Sending mail at periodic intervals: Select the Periodic timer

Option.

page 21

Interval time

Required when the trigger type is set to Word value change, Bit
value change
, or Periodic timer.

Mail address (desti-
nation)

Required.

Send user data

Required to send a user-set ASCII message in the e-mail body.

Send Error Log infor-
mation

Required to send the error log information in the e-mail body.

Send status informa-
tion

Required to send the Ethernet Unit's status in the e-mail body.

IO memory data

Required when the Send file data/IO memory data Option has
been selected and a data file is being attached (IO data (IOM),
IO data (CSV), or IO data (TXT)).

Attached file name

Required when the Send file data/IO memory data Option has
been selected.

CX-

Programmer

Unit Setup

Tab

Setting

Setting requirement

Reference