Omron CS CJ1W-ETN21 User Manual

Page 47

Advertising
background image

23

Using the Mail Send Function

Section 2-4

Attached File Name

Send Mail Trigger Type
Setting (Required)

Specifies the type send mail condition that will be used by the Ethernet Unit to
automatically send e-mail.

When the Mail Send Function is not being used, disable the send mail upon
trigger
setting.

Note

The same trigger type can be set for two or more trigger numbers (1 to 8).

Item

Contents

Default

Attached file
name

If the above setting is checked so that files can
be sent as attachments, then specify the name
of the file that is to be sent.

None

I/O data file
selected

The data file will be created auto-
matically with the file name
entered in this field.

Note Even if a filename extension

is entered, it will be ignored.
The Unit automatically adds
the appropriate extension
(.IOM, .TXT, or .CSV).

File data file
selected

The file with the specified filename
will be read from the Memory
Card's root directory and attached
to the e-mail.

Note The file must be located in

the Memory Card's root
directory in order to be sent
as an attachment.

Item

Contents

Default

Software switch

If this option is selected, an e-mail is sent when-
ever the Mail Send Switch goes from OFF to
ON.
The Mail Send Switch is bit 03 of word n in the
CIO Area words allocated to the Ethernet Unit
as a CPU Bus Unit. (n = 1500 + 25

× unit num-

ber)

Selected

Word value
change

If this option is selected, the value of a specified
word is compared with a set value with the
selected comparison function (=, <>, <, <=, >=,
or >), and an e-mail is sent whenever the condi-
tion is satisfied.
Specify the desired word address in the drop-
down lists.

Not selected

Bit value change If this option is selected, an e-mail is sent when-

ever the specified bit goes from OFF-to-ON or
ON-to-OFF. Specify the desired bit address in
the drop-down lists.

Not selected

ETN condition

If this option is selected, an e-mail is sent when-
ever a new error is stored in the Ethernet Unit's
error log.

Not selected

Advertising