86

PT

Limitations

PT with Touch Panels (DT

___

)

Touch switches 231 to 255 cannot be used.

PT with Function Keys (DF

___

)

Stand-alone operation is not supported.

PT without Function Keys (DN

___

)

12-key Function Key Units

Stand-alone operation is not supported.

32/16 Terminals

F1 to F12 and F17 to F29

10/02 Terminals

Numeral editing not supported. F1 to F10

can be used for stand-alone operation.

Operation

Select EXTEND from the Initial Edit Display to access the Extended Features
Display shown below. This display will appear only if direct connection is set
to No in the Tool Settings.

Extended Features Display

Use the following procedure to allocate screens to switches/function keys.

1, 2, 3... 1.

Press the Enter Key to access the Stand-alone Setting Display.

Stand-alone Operation

Section 2-15