1 installation, Installation -10 – Qualstar 501440 Rev. G User Manual

Page 23

Advertising
background image

4.5.1

Installation

The following steps outline the actions necessary to install a Fibre Channel Option
onto a library.

1.

Remove power from the TLS: first turn the power switch off and then remove the
power cord.

2.

Using a Phillips screwdriver remove the six screws securing the service panel on
the rear of the library – refer to Figure 4-8. Depending of the model of library,
the service panel may not have ventilation slots. Care must be taken to not re-
move the four screws securing the heatsink panels. Save the service panel for
possible future use.

Phillips Screws (6)

Do not remove

these screws

Do not remove
these screws

Figure 4-8 Service Panel

3.

Place the lower lip of the FCO inside the bottom edge of the service panel open-
ing and tilt the FCO upwards, making sure that the heatsink panel screws align
with the openings in the FCO. See Figure 4-9. The hinge surfaces should rest flat
against the rear of the library.

4.

Using a Phillips screwdriver, secure the FCO to the rear of the library at the
FCO’s two top captive screws. See Figure 4-9.

5.

Using two of the screws that were removed with the service panel, attach the
FCO’s two hinges to the rear of the library. See Figure 4-9.

FCO Type C Installation

501440 Rev. J

4-10

Advertising