Qualstar 501440 Rev. G User Manual

Page 31

Advertising
background image

The

Id Mode

menu item has two selections,

FIXED

or

SOFT

. If the mode is FIXED,

the

Loop Id

entry is displayed. If the

Id Mode

is SOFT, the Loop ID is automati-

cally assigned by the FCO.

During the Fibre Channel Arbitrated Loop (FC-AL) initialization process, a unique
Arbitrated Loop Physical Address (AL_PA) value is assigned to each port on the loop.
Not all of the 256 hex values are allowed as AL_PA values per FC-AL. The Loop Id
value is used to represent the 126 addresses that the FCO can use. Table 7-1 shows
how a Loop Id value maps to an AL_PA. If the Id Mode is “SOFT”, the FCO will at-
tempt to obtain an available Loop Id, in the following order: 0, 1, 2, etc.

4.8

Configuring the Fibre Channel SCSI Devices Interface

To establish the SCSI device configuration the Fibre Channel Option is commanded to
“Rescan” its three SCSI device buses. The three SCSI device channels, starting with
Channel 0, begin scanning for SCSI devices using ascending SCSI Target Ids. After all
three channels have been scanned, the FCO builds a SCSI device table, that it uses to
map SCSI Targets to the host as logical devices (LUNs).

C••••••Fibre•Channel
•Device
Id Mode 0: SOFT
Loop Id 0: nnn
Topology 0: LOOP

C••••••Fibre•Channel
•Device Left
•Device Right
L Id Mode 0: SOFT
L Loop Id 0: nnn
L Topology 0: LOOP
R Id Mode 0: SOFT
R Loop Id 0: nnn
R Topology 0: LOOP

Dual Bay Library

with two FCO’s

Single Bay or one side

of a Dual Bay Library

For single bay libraries or dual bay libraries with only one Fibre Channel Option in-
stalled, press the s (UP) or t (DOWN) key to move the pointer to

Device

. Press the

ENTER key to enter the

Configuration\Fibre Channel\Device

menu.

For dual bay libraries with two Fibre Channel Options installed, press the s (UP) or t
(DOWN) key to move the pointer to either

Device Left

or

Device Right

. The

left and right orientation is as viewed from the front of the library. Press the ENTER
key to enter the

Configuration\Fibre Channel\Device (Left or

Right)

menu.

The

Configuration\Fibre Channel\Device

menu panels display a list of

SCSI devices attached to the Fibre Channel Option. C TLS library with a single Fibre
Channel Option displays the title

CFC···········Device

. A dual-bay library

with two Fibre Channel Options installed, displays the title

CFC······Device

Left

or

CFC·····Device

Right

to correspond to the Fibre Channel Option in

the left and right side.

FCO Type C Installation

501440 Rev. J

4-18

Advertising