2 maintenance\fibre channel menu, 1 backplane id, 2 base lvl – Qualstar 501440 Rev. G User Manual

Page 72: Maintenance\fibre channel menu -4, Backplane id -4, Base lvl -4

Advertising
background image

8.2

Maintenance\Fibre Channel Menu

M......Fibre Channel
.Info
.Info Left
.Info Right
.Log
.Log Left
.Log Right

The Fibre Channel menu is partitioned into status screens, Info and Log. The Info
screen displays version and environmental information from the Fibre Channel Op-
tion. The Log screen accesses and displays the Fibre Channel Option’s internal event
log.

8.3

Maintenance\Fibre Channel\Info (Left or Right) Status Screen

MFC.............Info
MFC........Info Left
MFC.......Info Right
Backplane Id: ddd
Base Lvl: xxxxxxx
Board Rev: a
CPLD Rev: dd
Memory (MB): dddd
Daughtr Bd Id: ddd
FW Rev: aaaa
Loader Rev: aaaaa
Prod. Id.: aaaaaa
S/N: aaaaaa
+2.5V: ddd
+3.3V: ddd
+5V: ddd
+12V: dddd
Air Temp (C): +ddd
CPU Temp (C): +ddd
UPDATE

The Fibre Channel Info status screen displays the Fibre Channel Option’s configura-
tion and environmental information. The displayed information was obtained at
power-on, from the last configuration change, or from the last UPDATE request.

8.3.1

Backplane Id

This value identifies the type of backplane. The value of 001 should be displayed for
type B Fibre Channel Options. Type C FCOs will display the value of 007.

8.3.2

Base Lvl

This value identifies the base-level revision.