Toshiba XLTR-200 User Manual

Page 68

Advertising
background image

67

Table 5: Input Terminal Status Monitor (parameter 000D)

Bit Input

Terminal

0

1

Single-Bit

Read Mask

bit 0

F

terminal - CC open

terminal - CC shorted

0001

bit 1

R

terminal - CC open

terminal - CC shorted

0002

bit 2

S1

terminal - CC open

terminal - CC shorted

0004

bit 3

S2

terminal - CC open

terminal - CC shorted

0008

bit 4

S3

terminal - CC open

terminal - CC shorted

0010

bit 5

S4

terminal - CC open

terminal - CC shorted

0020

bit 6

S5 (option)

terminal - CC open

terminal - CC shorted

0040

Lower

Byte

bit 7

S6 (option)

terminal - CC open

terminal - CC shorted

0080

Bit Input

Terminal

0

1

Single-Bit

Read Mask

bit 0

unused (always 0)

bit 1

unused (always 0)

bit 2

unused (always 0)

bit 3

unused (always 0)

bit 4

unused (always 0)

bit 5

S7 (option)

terminal - CC open

terminal - CC shorted

0020

bit 6

RES

terminal - CC open

terminal - CC shorted

0040

Upper

Byte

bit 7

ST

terminal - CC open

terminal - CC shorted

0080

Table 6: Output Terminal Status Monitor / Inverter Status 2 (parameter 000E)

Bit Output

Terminal

0

1

Single-Bit

Read Mask

bit 0

unused (always 0)

bit 1

unused (always 0)

bit 2

FAN

OFF

ON

0004

bit 3

FL

FLB-FLC shorted FLA-FLC

shorted 0008

bit 4

MS relay

OFF

ON

0010

bit 5

OUT (option)

OUTB-OUTC shorted

OUTA-OUTC shorted

0020

bit 6

RCH

RCHA-RCHC open

RCHA-RCHC shorted

0040

Lower

Byte

bit 7

LOW

LOWA-LOWC open

LOWA-LOWC shorted

0080

Bit Inverter

Status

0

1

Single-Bit

Read Mask

bit 0

accelerating

not accelerating

accelerating

0001

bit 1

decelerating

not decelerating

decelerating

0002

bit 2

for inverter use

bit 3

retry

not retrying

retrying

0008

bit 4

running (including DC

injection braking)

stopped running

0010

bit 5

for inverter use

bit 6

for inverter use

Upper

Byte

bit 7

tripped

not tripped

tripped

0080

Advertising