13.7.13 AM/FM Terminal Adjustment Parameters

Parameter

Function / Title Bank

Mask Adjustment Range

Multiplier

0218

FM TERMINAL FUNCTION

SELECTION

0 / 1

FFFF

1194: Pre-comp ref. frequency

(0)

6686: Post-comp output freq.

(1)

1500: Frequency setting

(2)

2576: Output current

(3)

2689: DC voltage

(4)

5668: Output voltage

(5)

3684: Torque current

(6)

2688: Excitation current

(7)

7506: PID feedback value

(8)

0584: Motor overload ratio

(9)

0586: Inverter overload ratio

(10)

0588: DBR overload ratio

(11)

835C: Input power

(12)

835E: Output power

(13)

A000: Fixed output

(14)

2304: Peak output current

(15)

8302: Peak input voltage

(16)

0219

FREQUENCY METER

ADJUSTMENT

0 / 1

FFFF

0000

∼ FFFF

1

021A

AM TERMINAL FUNCTION

SELECTION

0 / 1

FFFF

Same as FM TERMINAL FUNCTION

SELECTION

021B

CURRENT METER

ADJUSTMENT

0 / 1

FFFF

0000

∼ FFFF

1