14 utility parameters – Toshiba XLTR-200 User Manual

Page 88

Advertising
background image

87

13.7.14 Utility Parameters

Parameter

Function / Title Bank

Mask

Adjustment Range

Multiplier

021C

INDUSTRIAL

APPLICATIONS
(previous setting monitor
for read use only)

0 / 1

00FF

0000: Standard shipment setting

(0)

0001: Pump application

(1)

0002: Fan application

(2)

0003: Conveyor application

(3)

0004: Hoist application

(4)

0005: Textiles application

(5)

0006: Machine tools application

(6)

021D

INDUSTRIAL

APPLICATIONS
(for write use)

(*)


0 / 1

00FF

0000: Does nothing

(0)

0011: Pump application

(1)

0012: Fan application

(2)

0013: Conveyor application

(3)

0014: Hoist application

(4)

0015: Textiles application

(5)

0016: Machine tools application

(6)

021E

STANDARD SETTING
MODE SELECTION

(*)

0 / 1

00FF

0000: Does nothing

(0)

0001: 50Hz standard settings

(1)

0002: 60Hz standard settings

(2)

0003: Factory settings

(3)

0004: Trip clear

(4)

0005: Save user-set parameters

(5)

0006: TYPE 5 reset

(6)

0007: Initialize typeform

(7)

021F

COMMAND MODE

SELECTION

0 / 1

0007

0000: Only RS232C valid

(0)

0001: Terminal input valid

(1)

0002: Panel input valid

(2)

0003: Communication interface input

valid (3)

0004: local/remote valid

(4)

0220

FREQUENCY MODE

SELECTION

0 / 1

0038

0000: Only RS232C valid

(0)

0008: Terminal input valid

(1)

0010: Panel input valid

(2)

0018: Communication/12-bit binary

interface input valid

(3)

0020: local/remote valid

(4)

0221

PANEL OPERATION

MODE SELECTION

0 / 1

00FB

0000

∼ 003F (0 ∼ 63)

(except 0004, 0008, 000C....)

1

0222

PASS NUMBER

0 / 1

00FF

0000

∼ 0063 (0 ∼ 99)

1

0223

CPU VERSION

2 FFFF

(Monitor

only)

0224

ROM VERSION

3 FFFF

(Monitor

only)

0225

EEPROM VERSION

1 FFFF

(Monitor

only)

0226

INVERTER TYPEFORM

0 00FF

(Monitor

only)

0227

STATUS MONITOR #1

DISPLAY SELECT

0 / 1

FFFF

0001

∼ 0010 (1 ∼ 16)

1

0228

STATUS MONITOR #2

DISPLAY SELECT

0 / 1

FFFF

0001

∼ 0010 (1 ∼ 16)

1

0229

STATUS MONITOR #3

DISPLAY SELECT

0 / 1

FFFF

0001

∼ 0010 (1 ∼ 16)

1

022A

STATUS MONITOR #4

DISPLAY SELECT

0 / 1

FFFF

0001

∼ 0010 (1 ∼ 16)

1

022B

FREQUENCY UNITS

SCALE FACTOR

0 / 1

FFFF

0000

∼ 4E20 (0.00 ∼ 200.00)

0.01

022C

FREQUENCY DISPLAY

RESOLUTION

0 / 1

0003

0000: 1Hz

(0)

0001: 0.1Hz

(1)

0002: 0.01Hz

(2)

Advertising