13.7.10 Pattern Run Control Parameters

Parameter

Function / Title Bank

Mask Adjustment

Range Multiplier

0146

PATTERN RUN SELECTION

0 / 1

0008

0000: OFF

(0)

0008: ON

(1)

0147 1

PATTERN RUN

CONTINUE MODE

0 / 1

0001

0000: reset on stop

(0)

0001: switch when done

(1)

0148

PATTERN GROUP #1

SPEED #0

1 00FF

0000:

Skip

(0) 1

0149

PATTERN GROUP #1

SPEED #1

0001

∼ 000F: Speeds 1 ∼ 15

0150

PATTERN GROUP #1

SPEED #2

0151

PATTERN GROUP #1

SPEED #3

0152

PATTERN GROUP #1

SPEED #4

0153

PATTERN GROUP #1

SPEED #5

0154

PATTERN GROUP #1

SPEED #6

0155

PATTERN GROUP #1

SPEED #7

0156

PATTERN GROUP #1

NUMBER OF CYCLES

0 / 1

00FF

0001

∼ 00FF: 1 ∼ 255

1

0157

PATTERN GROUP #2

SPEED #0

1 00FF

0000:

Skip

(0) 1

0158

PATTERN GROUP #2

SPEED #1

0001

∼ 000F: Speeds 1 ∼ 15

0159

PATTERN GROUP #2

SPEED #2

015A

PATTERN GROUP #2

SPEED #3

015B

PATTERN GROUP #2

SPEED #4

015C

PATTERN GROUP #2

SPEED #5

015D

PATTERN GROUP #2

SPEED #6

015E

PATTERN GROUP #2

SPEED #7

015F

PATTERN GROUP #2

NUMBER OF CYCLES

0 / 1

00FF

0001

∼ 00FF: 1 ∼ 255

1

0160

PATTERN GROUP #3

SPEED #0

1 00FF

0000:

Skip

(0) 1

0161

PATTERN GROUP #3

SPEED #1

0001

∼ 000F: Speeds 1 ∼ 15

0162

PATTERN GROUP #3

SPEED #2

0163

PATTERN GROUP #3

SPEED #3

0164

PATTERN GROUP #3

SPEED #4

0165

PATTERN GROUP #3

SPEED #5

0166

PATTERN GROUP #3

SPEED #6

0167

PATTERN GROUP #3

SPEED #7

0168

PATTERN GROUP #3

NUMBER OF CYCLES

0 / 1

00FF

0001

∼ 00FF: 1 ∼ 255

1

0169

PATTERN GROUP #4

SPEED #0

1 00FF

0000:

Skip

(0) 1

Advertising