12

ASCII Interface Module (AS311)

1. AS311 Overview




SW3

RS-232C/RS-422 selection switches (for channel 1)





























RSW1/RSW2

Optional rotary switches











SW3

ON

3

2

1

Used to select the interface of the channel 1 either
RS-232C or RS-422.
No.1

OFF ON

Interface

RS-232C

RS-422

Used to connect the terminating resistor (120

)

between RXDA and RXDB. (Effective for RS-422)
No.2

OFF ON

Terminating

Not connect

Connect

Used to connect the terminating resistor (120

)

between CTSA and CTSB. (Effective for RS-422)
No.3

OFF ON

Terminating

Not connect

Connect

NOTE

The switches No.2 and No.3 should be set to ON when the AS311
is configured as terminal station on the RS-422 transmission line.
The factory settings of the SW3 are all OFF.

RSW2

RSW1

C

4

8

0

C

4

8

0

Always set the RSW1 to 4 and the RSW2 to 0.
(Other settings are for future use)

Do not set other than above, otherwise the AS311