ASCII Interface Module (AS311)

5. Operation Procedure


5.1 Transmission message format


The transmission message is composed by ASCII characters and a specified trailing

code. The default setting of the trailing code is CR (carriage return code = H0D).

Refer to section 5.6 for setting the trailing code other than CR.


The maximum length of a message is 896 bytes. An example of the message is

shown

below.

1 2 3 4 5 6 7 8 9

0

1

2

A

B

7

8

9

CR



In the above figure,

x

means an ASCII character. For example,

0

is H30.


When the above message is received or transmitted, the data arrangements in the

T3 registers are as follows.







Register

F 8 7 0

n

1

0

n+1

A

2

n+2

7

B

n+3

9

8

n+4

CR

Transmission message

0

1

2

A

B

7

8

9

CR