User’s

Manual

53

6. RAS Information


6.2 Buffer memory information

Various RAS information are stored in the AS311’s buffer memory. These information

can be read by READ instruction. When some abnormality has occurred, check these

information.

6.2.1

Module

status


Address 4 of the buffer memory stores the AS311 module status.

F E D C B A 9 8 7 6 5 4 3 2 1 0

4

RDY

ERR

0 0 0 0 0 0

Error

code


Bit F

RDY (Ready)

1 = operating normally
0 = under initialization or error state

Bit E

ERR (Error)

1 = error state
0 = no error (normal)

Bit 7-0

Error code

Shows the detected error item if ERR is 1.
See the table below (H00 when normal)


Error

code

Type of error

Description

Status

H01

CPU error

CPU error has been detected
during initialization.

Operation is stopped.

H02

ROM error

ROM error has been detected
during initialization.

Operation is stopped.

H03

RAM error

Work RAM error has been
detected during initialization.

Operation is stopped.

H04 Buffer

memory

error

Buffer memory error has been
detected during initialization.

Operation is stopped.

H05 Switch

setting

abnormal

Switch setting abnormality has
been detected during
initialization.

Operation is stopped.

H10 Watchdog

timer error

Watchdog timer error has
occurred during operation.

Operation is stopped.
Cold reset will be
effective.

H11 Trap

interrupt

error

Trap interrupt has occurred by
detecting illegal instruction
during operation.

Operation is stopped.
Cold reset will be
effective.

H12 Buffer

memory

time-out error

Buffer memory time-out has
occurred during operation.

Operation is stopped.
Cold reset will be
effective.