30

ASCII Interface Module (AS311)

4. Register Configuration


Status and command (0 - 3)


The addresses 0 to 3 store the same data as the I/O registers that are assigned to the
AS311.
Refer to section 4.1 for details.

0

CH1 status

= XW(n)

1

CH2 status

= XW(n+1)

2

CH1 command

= YW(n+2)

3

CH2 command

= YW(n+3)


Status 1 (4)


The address 4 shows the AS311 module status. If an error has occurred in the AS311,
the error code is stored here.

F E D C B A 9 8 7 6 5 4 3 2 1 0

4

RDY

ERR

0 0 0 0 0 0

Error

code


Bit F

RDY (Ready)

1 = operating normally
0 = under initialization or error state

Bit E

ERR (Error)

1 = error state
0 = no error (normal)

Bit 7-0

Error code

Shows the detected error item if ERR is 1.
(H00 when normal)
See section 6.2.1 for details.


RSW1/2 information (5)


The address 5 stores the rotary switches RSW1 and RSW2 setting status.

F E D C B A 9 8 7 6 5 4 3 2 1 0

5

0 0 0 0 0 0 0 0

RSW1

RSW2


Bit 7-4

RSW1

Stores the rotary switch 1 (RSW1) setting status.
0 - F

Bit 3-0

RSW2

Stores the rotary switch 2 (RSW2) setting status.
0 - F