Toshiba AS311 User Manual

Page 37

Advertising
background image

User’s

Manual

35

4. Register Configuration


CH1 time-out check (25) and
CH2 time-out check (89)


The address 25 (for channel 1) and the address 89 (for channel 2) store the time-out
check times. If the time between each receiving character exceeds the specified time-out
check time, it becomes the receiving time-out error. The default setting is 1 second.
To change the setting, write the desired data into this address then write the hot reset
command into the Command 1 (12). See section 5.7 for this procedure.

F E D C B A 9 8 7 6 5 4 3 2 1 0

25 or 89

Time-out check time


Bit F-0

Time-out check
time

Stores the time-out check time (0.1 s units).
Valid data range is 1 to 600 (0.1 to 60 s). If 0 or more
than 600 is specified, the time-out check will not work.
Initial value at power on is 10 (1 s).