4. Register Configuration


CH1 receive length (19) and
CH2 receive length (83)


The address 19 (for channel 1) and the address 83 (for channel 2) indicate the length of
the received message (number of bytes). This information is set during the received
message read sequence.

F E D C B A 9 8 7 6 5 4 3 2 1 0

19 or 83

Received message length


Bit F-0

Received
message length

Shows the received message length (bytes).
0 - 896


CH1 trailing code (24) and
CH2 trailing code (88)


The address 24 (for channel 1) and the address 88 (for channel 2) store the trailing
codes. The default setting is H0D (CR code).
To change the trailing code, write the desired code into this address then write the hot
reset command into the Command 1 (12). See section 5.6 for this procedure.

F E D C B A 9 8 7 6 5 4 3 2 1 0

24 or 88

0 0 0 0 0 0 0 0

Trailing

code


Bit 7-0

Trailing code

Stores the trailing code.
Initial value at power on is H0D (carriage return).